Error Codes
CAN"Controller area network" CAN is a broadcast, differential serial bus standard developed for connecting electronic control units. Each node is able to send and receive messages, but not simultaneously Emergency Code | AKD2G Number | Message |
---|---|---|
3110h | F2015 | Bus over voltage FPGA"Field-Programmable Gate Array" FPGA is a semiconductor device that can be configured by the customer or designer after manufacturing; hence the name "field-programmable". |
3120h | F2000 | Vbus read is out of thresholds. |
3130h | F2008 | Bus capacitor overloaded. |
3180h | W2008 | Bus capacitor overloaded. |
3181h | F2014 | AC input phase loss. |
3182h | F2016 | Gate supply under voltage. |
3183h | W1000 | Fan stalled. |
3190h | F1005 | Unrecognized FPGA fault. |
3191h | F1006 | FPGA cyclic read fault. |
3210h | F2006 | Bus over voltage. |
3220h | F2007 | Bus under voltage. |
3280h | W2007 | Bus under voltage. |
3281h | W2010 | Regen energy critical. |
3282h | F2013 | Regen short circuit. |
3283h | W2006 | Bus over voltage. |
4210h | F2500 | Control over temperature sensorA sensor is a type of transducer that converts one type of energy into another for various purposes including measurement or information transfer. |
4310h | F2501 | Power over temperature sensor. |
4382h | F1001 | Power board type mismatch detected. |
4390h | W2500 | Control Over Temp SensorA sensor is a type of transducer that converts one type of energy into another for various purposes including measurement or information transfer. |
4391h | W2501 | Power Over Temp Sensor. |
4394h | W2502 | Control Under Temp Sensor. |
4395h | W2503 | Power Under Temp Sensor. |
4398h | F2502 | Control under temperature sensor. |
4399h | F2503 | Power under temperature sensor. |
5580h | F1100 | NV Memory Data (might occur when downloading firmware). |
5588h | F1101 | Flash directory error. |
5590h | F1102 | Identity read failed. |
5591h | F1103 | Invalid MAC Address. |
55A1h | F1104 | Power board factory settings file read failed. |
55A2h | F1105 | Power board updateable settings file read failed. |
55B0h | F1106 | Failure reading Control Board FPGA EDS file. |
55B1h | F1107 | Power Board Resident FPGA not valid. |
55B2h | F1108 | Power Board Operational FPGA not valid. |
55B3h | F1109 | Failure reading Power Board FPGA EDS. |
55C4h | F1002 | Power Board Communication fault. |
55C5h | F1003 | Power Board FPGA not configured. |
6080h | F3000 | Issued command timed out. |
6380h | F5005 | Drive motor parameters setup incomplete. |
6381h | F3001 | Failed to default parameters. |
7180h | F5000 | Motor overheated. |
7184h | F5003 | Brake applied when it should be released. |
7186h | W5000 | Motor Temperature high. |
7187h | F2011 | Voltage exceeds motors rating. |
7188h | F2009 | Regen near capacity, could not prevent over voltage. |
7189h | F5004 | Brake released when it should be applied. |
718Ah | F2018 | Broken Wire Connection to Motor. |
7190h | F5001 | Brake 1 current out of range. |
7191h | W5001 | Brake override active. |
7192h | F5002 | Brake 2 current out of range. |
7193h | F5006 | Temperature sensor detected open circuit. |
7194h | W5007 | Brake override active but no brake configured. |
7380h | F4100 | Feedback: Parity fault. |
7381h | F4101 | Feedback: Overrun fault. |
7382h | F4102 | Feedback: Framing fault. |
7383h | F4103 | Feedback: CRC"Cyclic redundancy check" A CRC is a type of function that takes as input a data stream of any length and produces as output a value of a certain fixed size. The term CRC is often used to denote either the function or the function's output. A CRC can be used as a checksum to detect accidental alteration of data during transmission or storage fault. |
7384h | F4104 | Feedback: Communication Timeout fault. |
7385h | F4105 | Feedback: Initialization sequence fault. |
7386h | F4106 | Feedback: Temperature fault. |
7387h | F4107 | Feedback: Battery fault. |
7388h | F4108 | Feedback: Sensor fault. |
7389h | F4109 | Feedback: Device-unique fault 0. |
738Ah | F4110 | Feedback: Device-unique fault 1. |
738Bh | F4111 | Feedback: Analog Signal fault. |
738Ch | F4112 | Feedback: Broken Wire fault. |
738Dh | F4113 | Feedback: Power Supply fault. |
738Eh | F4114 | Feedback: Illegal Hall state (111, 000). |
738Fh | F4115 | Failed to set feedback type. |
7392h | F4116 | Failed to read motor parameters from feedback deviceA process whereby some proportion of the output signal of a system is passed (fed back) to the input. In automation, a device coupled to each motor to provide indication of the motor's shaft angle, for use in commutating the motor and controlling its speed and position. |
7393h | F4117 | SFA communication fault. |
7394h | F4118 | SFA over current. |
7395h | F4119 | SFA under voltage. |
7396h | F4120 | Feedback: Safety fault. |
7397h | F3004 | Operation in Position Mode with Halls Only feedback not allowed. |
7398h | F4121 | Feedback: Watchdog fault. |
7399h | F4122 | Unrecognized feedback fault. |
739Ah | F4123 | SFA Resident FPGA not valid. |
739Bh | F4124 | SFA Operational FPGA not valid. |
739Ch | F4125 | SFA FPGA file read failed. |
739Dh | F4126 | SFA Factory file read failed. |
739Eh | W4100 | Feedback parity. |
739Fh | W4101 | Feedback overrun. |
73A0h | W4102 | Feedback framing. |
73A1h | W4103 | Feedback CRC. |
73A2h | W4104 | Feedback communication timeout. |
73A3h | W4105 | Feedback initialization sequence. |
73A4h | W4106 | Feedback temperature. |
73A5h | W4107 | Feedback battery. |
73A6h | W4108 | Feedback sensor. |
73A7h | W4109 | Feedback device-unique warning 0. |
73A8h | W4110 | Feedback device-unique warning 1. |
73A9h | W4111 | Gearing feedback source fault. |
73C0h | F5500 | Wake and Shake - Insufficient movement |
73C1h | F5501 | Wake and Shake - Excess movement |
73C2h | F5502 | Wake and Shake - Fine-Coarse delta too large. |
73C3h | F5503 | Wake and Shake - Over speed |
73C4h | F5504 | Wake and Shake - Loop angle delta too large. |
73C5h | F5505 | Wake and Shake - Commutation not initialized. |
73C6h | F5506 | Wake and Shake - Motor U phase missing. |
73C7h | F5507 | Wake and Shake - Motor V phase missing. |
73C8h | F5508 | Wake and Shake - Motor W phase missing. |
73C9h | W5500 | Wake & Shake configured or active. |
73D0h | F5509 | Wake and Shake - Validating Positive Movement Failed. |
73D1h | F5510 | Wake and Shake - Validating Negative Movement Failed. |
73D2h | F5511 | Wake and Shake - Validating Comm. angle timed out. |
73D3h | F5512 | Wake and Shake - Validating Comm. angle moved too far - Bad Comm Angle. |
73D4h | F5513 | Wake and Shake - Validating Comm. angle required more than MOTOR.ICONT |
73D5h | F6002 | Invalid commutation detected - motor accelerating in the wrong direction. Motor phase may be incorrect. |
8130h | F7002 | FieldbusA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design Heartbeat lost. |
8180h | W7000 | Fieldbus Error Passive. |
8311h | F2017 | Motor Foldback. |
8331h | F2001 | Drive Foldback. |
8380h | W2001 | Drive foldback imminent! Reduce Load. |
8381h | W2002 | Motor foldback imminent! Reduce Load. |
8382h | W2003 | Motor I2t load! Reduce load. |
8383h | W6008 | Using derivative of position when using sensorless feedback type in position mode |
8384h | W6004 | Zero velocity when using induction sensorless feedback type in torqueTorque is the tendency of a force to rotate an object about an axis. Just as a force is a push or a pull, a torque can be thought of as a twist mode. |
8385h | W6027 | Current Command Saturated. |
8386h | F5514 | Wake and Shake - Limit Switch Hit |
8480h | F6000 | Over speed. |
8481h | F6005 | Emergency timeout occurred. |
8582h | W6006 | Positive Limit Switch triggered. |
8583h | W6007 | Negative Limit Switch triggered. |
8611h | F6001 | Following error magnitude fault. |
8685h | F6003 | Instability during autotune. |
8688h | W6000 | Velocity Limit Violation, Exceeding Max Limit. |
8689h | W6009 | Following Motion Failed; Check Motion Parameters . |
868Ah | W6010 | Target Position crossed due to Stop command. |
86A0h | W6011 | HomingThe Homing procedure allows, based on a position measurement, to set a position offset to the motor in order to ensure it is physically at the home position Index pulse not found. |
86A1h | W6012 | Home switch not found. |
86A3h | W6014 | Motion Task Activation Failed. |
86A4h | W6015 | Homing Failed. |
86A5h | F6004 | Target position was overshot due to invalid motion task activation. |
86A8h | W6017 | Motion task target position is out of modulo-range. |
86A9h | W6018 | Motion task target position is out of software-limits. |
86AAh | W6019 | Invalid bit-combination in the motion-task control-word. |
86ABh | W6020 | 1:1 profile can not be triggered on-the-fly. |
86ACh | W6021 | Customer profile table is not initialized. |
86ADh | W6022 | Motion task activation is currently pending. |
86AEh | W6002 | Homing is needed. |
86AFh | W6023 | Homing maximum distance exceeded. |
8780h | F7001 | Fieldbus Sync frames lost. |
8781h | W7001 | PLL unlocked. |
8782h | F7003 | PLL failed to acquire lock. |
8783h | F7004 | PLL lost lock. |
8784h | F7005 | Fieldbus cyclic setpoints missing. |
8AF0h | W6025 | Homing and feedback mismatch. |
FF00h | W2011 | No Power on IO 24V Rail. |
FF01h | F7000 | Fieldbus Communication lost. |
FF02h | F2004 | Iu current offset limit exceeded. |
FF03h | F2005 | Iv current offset limit exceeded. |
FF04h | F2010 | Regen over power. |
FF05h | F3100 | MechaWare Model failed to connect Analog Input, fix model. |
FF06h | F3101 | MechaWare Model failed to connect Analog Output, fix model. |
FF07h | F2002 | Output over current. |
FF08h | F2003 | Current sensor short circuit. |
FF09h | F3002 | Assert check failed. |
FF0Ah | F2012 | Power stage fault. |
FF0Bh | F9000 | Safe torque off. |
FF0Ch | W9000 | Safe torque off. |
FF0Dh | F1000 | Firmware and FPGA versions are not compatible. |
FF0Eh | W6001 | Exceeding following error magnitude warning level. |
FF0Fh | F3003 | External Fault. |
FF10h | W6003 | OPMODE incompatible with CMDSOURCE. |
FF11h | F1004 | Failed to initialize the system. |
FF12h | F5100 | IL"Instruction list" This is a low-level language and resembles assembly.FBSOURCE has unidentified feedback selected. |
FF13h | F5101 | VL.FBSOURCE has unidentified feedback selected. |
FF14h | F5102 | PL.FBSOURCE has unidentified feedback selected. |
FF15h | F1007 | A Factory MechaWare model failed to load. |
FF16h | F1008 | A User MechaWare model failed to load. |
FF17h | W6028 | Gear feedback source is invalid. |
FF18h | F6028 | Gearing feedback source is invalid. |
FF19h | F6006 | Current home mode requires HOME.IPEAK to be set. |
FF1Ah | W6026 | Current homing mode requires HOME.IPEAK to be set by user |
FF50h | F9002 | SMM Communication Failed. |
FF51h | F9003 | Incorrect safety card detected. |
FF52h | F9004 | Safe torque off pulse and standard lines don't match. |
FF53h | F9005 | Simultaneity Fault: Safe torque off lines don't match each other. |
FF54h | W9011 | SMM I/O failure detected |
FF55h | F9006 | SMM in failed state. |
FF56h | W9008 | Brake Test Time Overflow. |
FF57h | W9009 | SMM Over Temperature. |
FF58h | W9010 | SMM State Not Operational. |
FF59h | W9007 | Safe brake parameters inconsistent |
FF5Ah | F9007 | Safe brake parameters inconsistent. |